Contents - Index


REFERENCE (Macro Command)

 

REFERENCE Fluid ReferenceID

 

The REFERENCE macro command allows the default reference state for a specified fluid to be changed.

Fluid is the name of the fluid, e.g., R134a. The fluid name can also be provided with a previously-defined string variable, e.g., R$

ReferenceID is one of the following:

DFT the reference is reset to the default value. See the fluid property information for the specified fluid to determine the default reference state

NBP  the values of specific enthalpy and specific entropy are each set to 0 for saturated liquid at the normal boiling point. Note that this option is not applicable to fluids for which the critical pressure is less than one atmosphere. In this case, the reference will be reset to the default value.

ASH  the values of specific enthalpy and specific entropy are each set to 0 for saturated liquid at -40 C (-40 F). This is the ASHRAE standard reference. Note that this option is not applicable to fluids for which the critical temperature is less than -40 C. In this case, the reference will be reset to the default value. 

IIR  the value of specific enthalpy is set to 200 kJ/kg and the value of specific entropy is set to 1.0 kJ/kg-K for saturated liquid at 0 C (273.15 K). This is the standard reference state for the International Institute of Refrigeration. Note that this option is not applicable to fluids for which the critical temperature is less than 0 C. In this case, the reference will be reset to the default value. 

 

Example:

REFERENCE R134a IIR