Contents - Index


MODE = DEWT (2)

 

Description: Dew point calculation for a given temperature

     In1  = temperature in K

     In2  = mole fraction of first component in saturated vapor (skip for pure fluid)

     ...

     InN  = mole fraction of next to last component

 

     Out1 = Temperature in K  (same as In1)

     Out2 = Pressure of saturated vapor in Pa      

     Out3 = Density of saturated vapor in gmol/m3

     Out4..OutN = Mole fractions of each component in the liquid phase at equilibrium with the liquid

 

Notes:  This Mode is intended for use with mixtures.  There will not be any mole fractions in the outputs for a pure fluid.

 

Example: 

DEWT=2      "mode for dew point calculation at a given temperature - this is not needed if the $INCLUDE EES_COOLPROP.txt directive is used"

Tin=350 [K]  "temperature"

mf=0.3         "mole fraction"

$VarInfo TL units=K

$VarInfo PL units=Pa

$Varinfo DL units=gmol/m3

F$='R32+R134a'

CALL EES_COOLPROP(F$, mf, DEWT, Tin: TL, PL, DL, y_32, y_134a)

 

{Solution:

DEWT=2 

DV=1809 [gmol/m3]

F$='R32+R134a'

mf=0.3 

PV=3.053E+06 [Pa]

Tin=350 [K]

TV=350 [K]

x_134a=0.775 

x_32=0.225 

}

 

 

Return