Contents - Index


Pin-fin plate-fin, surface PF-4(F)

 

 

Procedure Compact_HX_ND('pf_plate-fin_sPF-4F', Re: f,j_H) is a non-dimensional procedure that returns the friction factor and the Colburn j factor for external flow through a pin-fin plate-fin heat exchanger with surface PF-4F given the Reynolds number. The values calculated are based on a best fit curve to experimental data. These data are from Kays and London (1984) p. 260.   

 

Related procedures include:

Geometry-(more info)

CHX_geom_plate_fin('pf_plate-fin_sPF-4F', a, b_2: b_1, D_o, fin_pitch, D_h, fin_thk, sigma, alpha, A_fin\A)

Coefficient of heat transfer-(more info)

CHX_h_plate_fin('pf_plate-fin_sPF-4F', a, b_2, m_dot, A_fr, Fluid$,T, P:h)

Pressure drop-(more info)

CHX_DELTAp_plate_fin('pf_plate-fin_sPF-4F', a, b_2, m_dot, A_fr, L, Fluid$, T_i, T_o, P: DELTAp)

 

Additional Information

Pin diameter = 1.65e-3 m

Pin pitch parallel to flow = 3.175e-3 m

Pin pitch perpendicular to flow = 5.055e-3 m

Plate spacing, b =12.75e-3

D_h = 5.66e-3 m

Total heat transfer area/volume between plates (Beta) = 459 m^2/m^3

Fin area/total area = 0.704

 

 